How to set General Behavior Sanlytics on SmartPSS

  119   SmartPSS

Introduction to the text

How to set General Behavior Sanlytics on SmartPSS

Description

This article will show you how to set General Behavior Sanlytics on SmartPSS

Prerequisites

  • SmartPSS
  • IPC, NVR

Step by Step Instructions

1. Config IVS Channel

IVS includes general behavior analytics; face recognition, people count, heat map and etc., different devices support different IVS plans, which subject to actual interface.

Note:

  • IVS analytics only detects IVS analytics capacity of connected device.

Speed dome or PTZ device support scene config and preset selection, IPC do not support scene config.

Set IVS analytics refer to continuous setup in this chapter.

If you need a static scene, you can click to stop video; click to continue playing.

2. Scene Config

For example to device to add is speed dome or PTZ device, then it supports to set preset in scene config interface, and you can set different plans for preset.

Add Preset

Step 1

In Scene interface, click Add Scene.

Step 2

Via PTZ direction control, rotate camera to designated position.

Note:

Step length can control PTZ speed, within 1~8 step length.

Step 3

Click Save.

3. Modify Preset

Step 1

In Scene interface, select preset to modify.

Step 2

Via PTZ direction control, rotate camera to designated position

Note:

Step length can control PTZ speed, within 1~8 step length.

Step 3

Click Save.

4. Delete Preset

Step 1

In Scene interface, select preset to delete.

Step 2

Click Delete.


5. General Behavior Analytics

After you enable behavior analytics, you can tripwire, perimeter protection and etc. Refer to actual front-end device.

(1)Enable Behavior Analytics

Step 1

In Scene interface, when preset setup is complete, click Next.

Step 2

Select scene.

Step 3

Click and select IVS plan.

(2 )Calibration

According to user marked 1 horizontal line and 3 vertical lines, and corresponding actual distance, it can estimate internal parameter and external parameter in order to confirm relationship between gotten 2D image and 3D actual object.

Step 1

In Smart Plan interface select plan and click Next or config,

Step 2

Click Region, and draw region in window, when you complete, right click to end.

Step 3

Set ruler length, click . Draw vertical rule and left click to end drawing.

Repeat this step to draw 3 vertical rulers. Shape of triangle is recommended.

Step 4

Set horizontal rule angle, click , and draw 1 horizontal line in region, left click to end.

Note:

  • Select vertical or horizontal rule, click redraw to draw rule. Select region, click redraw is you want to draw again region, vertical ruler and horizontal ruler.
  • Select vertical or horizontal ruler, click Delete to delete ruler. Select region, click Delete to delete region, vertical ruler and horizontal ruler together.

Step 5 Click Apply to save.

Step 6

(Optional) vertically or horizontally measure distance.

Click V-measure, and draw vertical line in region, system shows all drawn vertical line length.

Click H-measure, and draw horizontal line in region, system shows all drawn horizontal line length.


(3)Set Detection Zone

You can set region of IVS analysis.

Step 1 Click .

Step 2

Click Detection Zone, in video window, draw detection zone and right click to stop drawing.

Step 3

Click Excluded Zone, in detection zone draw excluded zone, and right click to stop drawing.

Note:

Select excluded zone, click Re-draw to draw again. Selected detection, click Re-draw to redraw detection and excluded zone.

Select excluded zone, click Delete to delete zone. Selected detection, click Delete to delete detection and excluded zone

LEAVE A COMMENT