How to set Missing Object Detection on SmartPSS

  111   SmartPSS

Introduction to the text

How to set Missing Object Detection on SmartPSS

Description

This article will show you how to set IVS rules ‘Missing Object Detection’ on SmartPSS

Prerequisites

  • SmartPSS

Step by Step Instructions

In Smart Plan interface, select Next or config, here you can set IVS.

Missing Object

When an object is moves out from detection zone, alarm is triggered.

Step 1

Click Add rule.

Step 2

Enable rule and modify rule name and type.

1. Enable rule, means to enable corresponding IVS rule.

2. Modify rule name.

3. In Rule type dropdown list, select Missing object.

Step 3

In monitoring video, draw detection zone, and right click to stop drawing.

Note:

Select existing detection zone, click Clear or Re-draw to draw again.

Step 4

Set parameter, arm time and alarm link. Draw target filter

ParameterNote
Min DurationMin time period between the object leaves detection zone and alarm trigger.

Step 5

Click Apply.